Huronwoods Annual Water Report 2006
O.Reg 170 SECTION 11 ANNUAL REPORT
220007775
Drinking-Water System Number:
Huron Woods Water Supply Works
Drinking-Water System Name:
Town of South Bruce Peninsula
Drinking-Water System Owner:
Small Municipal Residential
Drinking-Water System Category:
January 1, 2006 to December 31, 2006
Period being reported:
Complete if your Category is Large Municipal Complete for all other Categories.
Residential or Small Municipal Residential
Does your Drinking-Water System serve Number of Designated Facilities served:
more than 10,000 people? Yes [ ] No [X]
Is your annual report available to the public Did you provide a copy of your annual
at no charge on a web site on the Internet? report to all Designated Facilities you
Yes [X] No [ ] serve?
Yes [ ] No [ ]
Location where Summary Report required
under O. Reg. 170/03 Schedule 22 will be Number of Interested Authorities you
available for inspection. report to:
Town of South Bruce Peninsula
Did you provide a copy of your annual
315 George Street
report to all Interested Authorities you
Wiarton, Ontario
report to for each Designated Facility?
N0H 2T0
Yes [ ] No [ ]
519-534-1400
List Drinking-Water Systems, which receive all of their drinking water from your
system:
N/A
Did you provide a copy of your annual report to all Drinking-Water System owners
that are connected to you and to whom you provide all of its drinking water?
Yes [ ] No [ ] N/A [X]
Indicate how you notified system users that your annual report is available, and is free
of charge.
[X] Public access/notice via the web
[X] Public access/notice via Government Office
[ ] Public access/notice via a newspaper
[ ] Public access/notice via Public Request
[ ] Public access/notice via a Public Library
[ ] Public access/notice via other method _______________________________________
Page 1 of 6
O.Reg 170 SECTION 11 ANNUAL REPORT
Describe your Drinking-Water System
Class 1 Water Distribution
The Huron Woods drinking-water system in the Town of South Bruce Peninsula consists of four
wells:
- Well No. W1 and old disused Pumphouse
- Well No. W2
- Well No. W3
- Well No. W6 and existing Pumphouse
The Well No. W1 is rated at 1.21 L/s at a TDH of 83.3 m. The Well No. W2 is rated at 0.6 L/s at a
TDH of 74.2 m.. The Well No. W3 is rated at 1.51 L/s at a TDH of 105 m and the Well No. W6 is
rates at 5.3 L/s at a TDH of 47.6 m.
The existing Pumphouse consists of a Ferrosand Filter system, cartridge filter system, ultraviolet
(UV) disinfection system, chlorination system, filter backwash tank, jockey pump, flow control
valves (hydraulic), and water meters.
The Ferrosand Filter system consists of two Ferrosand Filter units (one duty, one standby) connected
to the common well discharge header, complete with PLC to control backwash cycles,
hydropneumatic tank to drive hydropneumatic valves, and all necessary piping and appurtenances. An
iron-oxidizing sodium hypochlorite feed system with injection point located prior to the Ferrosand
Filter units, consisting of two feed pumps (one duty, one standby) with auto switchover. There are
two submersible well pumps (one duty, one standby) each rated at 20.3 L/s at a TDH of 19.5 m for
the purpose of backwashing Ferrosand Filter units.
The Cartridge Filter system located after the Ferrosand Filter units has a treatment capacity of
9.55 L/s, equipped with a 5-micron size cartridge.
The UV disinfection system has two UV disinfection reactors (one duty, one standby) located after
the cartridge filter unit, capable of providing a minimum dose of 40 mJ/cm2 at end of lamp life and
each rated at 9.55 L/s. Each UV reactor has an automatic cleaning system and an on-line UV intensity
monitor with alarm.
The Chlorination System has a secondary-chlorination sodium hypochlorite disinfection system with
injection point located prior to the treated water entering the reservoir cells, consisting of two
metering pumps (one duty, one standby) with auto switchover. There is also a post-chlorination
sodium hypochlorite disinfection system with injection point located at the high lift header. It consists
of two metering pumps (one duty, one standby) complete with all associated piping and alarms.
The Filter Backwash Tank is one in-ground cast-in-place concrete tank to clarify filter backwash
waste with clarified supernatant discharged by gravity to an existing ditch.
The jockey pump is a submersible well pump rated at 5.67 L/s at a TDH of 56 m within Reservoir
Cell No. 2.
One of the hydraulic flow control valves is located on the inlet piping from Well No. W1 and Well
No. W2 set at 1.21 L/s. Another flow control valve is located in the inlet piping from Well No. W3
Page 2 of 6
O.Reg 170 SECTION 11 ANNUAL REPORT
set at 1.51 L/s. One flow control valve is located on the inlet piping from Well No. W6 set at 5.3 L/s.
The last flow control valve is located on the combined piping from the two backwash pumps set at
20.3 L/s.
There are three water meters:
- One raw water meter for the raw water header
- One total raw water meter located after the common header from all four production wells
- One treated water meter prior to treated water exiting the pumphouse
The 80 kW diesel generator is set with a double-walled sub-base fuel tank with level gauge, low level
float switch and leak sensor, all to be housed in the diesel generator building.
The Huron Woods system also contains one programmable logic controller (PLC) and associated
SCADA system for control of plant operations.
List all water treatment chemicals used over this reporting period
- Sodium Hypochlorite 12%
Were any significant expenses incurred to?
[X] Install required equipment
[X] Repair required equipment
[X] Replace required equipment
Describe
Drinking water system upgraded in 2006
-
Provide details on the notices submitted in accordance with subsection 18(1) of the Safe
Drinking-Water Act or section 16-4 of Schedule 16 of O.Reg.170/03 and reported to
Spills Action Centre
Incident Parameter Result Unit of Corrective Action Corrective
Date Measure Action Date
06/30/06 Possible compromise Sample (bacti) 06/30/06
AWQI to disinfection 16.4** Sample
#65450 Results OK.
09/27/06 Total Coliform 1.0 CFU/ Resample 09/27/06
AWQI 100ml Resample Ok
#68138
**Reported to SAC as precautionary measures only No adverse occurred
Page 3 of 6
O.Reg 170 SECTION 11 ANNUAL REPORT
Microbiological testing done under section 8-2 during this reporting period
Number Range of Range of Number Range of HPC
of E.Coli Or Total of HPC Samples Results (#-#)
Samples Fecal Coliform Or Or
Results Results Background Background
(#-#) (#-#) Colony Counts Colony Counts
47 0-0 0-30 0 0-0
Raw
4 0-0 0-4 4 0-1
Treated
56 0-0 0-1 56 0-1
Distribution
Operational testing done under Schedule 7, 8 or 9 during the period covered by this
Annual Report.
Number of Range of Results
NOTE: For continuous
Grab Samples (#-#)
monitors use 8760 as the
number of samples.
8760 0.01-0.71
Turbidity
8760 0.53-2.3
Chlorine
420 0.27-2.2
Chlorine Residual
Distribution
System
NOTE: Record the unit of measure if it is not milligrams per litre.
Summary of additional testing and sampling carried out in accordance with the
requirement of an approval or order.
Date of order or C of A Parameter Date Sampled Result C of A Unit of
Limit Measure
C of A 7203-6LVST4 Suspended Solids Quarterly Annual 25 mg/L
(composite) Average
4.6
Summary of Inorganic parameters tested during this reporting period or most recent
Parameter Sample Date Result Value Unit of Measure Exceedance
01/11/06 <0.6 ug/L No
Antimony
01/11/06 <2 ug/L No
Arsenic
01/11/06 20 ug/L No
Barium
01/11/06 15 ug/L No
Boron
01/11/06 <0.1 ug/L No
Cadmium
01/11/06 <3 ug/L No
Chromium
01/11/06 <0.1 ug/L No
Lead
01/11/06 <0.02 ug/L No
Mercury
01/11/06 <3 ug/L No
Selenium
11/15/01 ND mg/L No
Sodium
01/11/06 <0.05 ug/L No
Uranium
01/22/02 0.8 mg/L No
Fluoride
Page 4 of 6
O.Reg 170 SECTION 11 ANNUAL REPORT
01/11/06 <0.005 mg/L No
Nitrite
04/25/06 <0.005 mg/L No
07/10/06 <0.005 mg/L No
10/10/06 <0.005 mg/L No
01/11/06 <0.013 mg/L No
Nitrate
04/25/06 0.013 mg/L No
07/10/06 0.024 mg/L No
10/10/06 0.024 mg/L No
Summary of Organic parameters sampled during this reporting period or most recent
Parameter Sample Result Unit of Exceedance
Date Value Measure
01/11/06 <0.11 ug/L No
Alachlor
01/11/06 <0.30 ug/L No
Aldicarb
01/11/06 <0.067 ug/L No
Aldrin + Dieldrin
01/11/06 <0.12 ug/L No
Atrazine + N-dealkylated metobolites
01/11/06 <0.21 ug/L No
Azinphos-methyl
01/11/06 <0.13 ug/L No
Bendiocarb
01/11/06 <0.36 ug/L No
Benzene
01/11/06 <0.004 ug/L No
Benzo(a)pyrene
01/11/06 <0.094 ug/L No
Bromoxynil
01/11/06 <0.16 ug/L No
Carbaryl
01/11/06 <0.37 ug/L No
Carbofuran
01/11/06 <0.34 ug/L No
Carbon Tetrachloride
01/11/06 <0.11 ug/L No
Chlordane (Total)
01/11/06 <0.18 ug/L No
Chlorpyrifos
01/11/06 <0.18 ug/L No
Cyanazine
01/11/06 <0.081 ug/L No
Diazinon
01/11/06 <0.17 ug/L No
Dicamba
01/11/06 <0.56 ug/L No
1,2-Dichlorobenzene
01/11/06 <0.25 ug/L No
1,4-Dichlorobenzene
01/11/06 <0.14 ug/L No
Dichlorodiphenyltrichloroethane (DDT) +
metabolites
01/11/06 <0.32 ug/L No
1,2-Dichloroethane
01/11/06 <0.52 ug/L No
1,1-Dichloroethylene
(vinylidene chloride)
01/11/06 <1.17 ug/L No
Dichloromethane
01/11/06 <0.15 ug/L No
2-4 Dichlorophenol
01/11/06 <0.19 ug/L No
2,4-Dichlorophenoxy acetic acid (2,4-D)
01/11/06 <0.13 ug/L No
Diclofop-methyl
01/11/06 <0.12 ug/L No
Dimethoate
01/11/06 <0.084 ug/L No
Dinoseb
01/11/06 <1 ug/L No
Diquat
01/11/06 <0.087 ug/L No
Diuron
01/11/06 <6 ug/L No
Glyphosate
01/11/06 <0.11 ug/L No
Heptachlor + Heptachlor Epoxide
01/11/06 <0.056 ug/L No
Linadane (Total)
Page 5 of 6
O.Reg 170 SECTION 11 ANNUAL REPORT
01/11/06 <0.091 ug/L No
Malathion
01/11/06 <0.14 ug/L No
Methoxychlor
01/11/06 <0.092 ug/L No
Metolachlor
01/11/06 <0.12 ug/L No
Metribuzin
01/11/06 <0.46 ug/L No
Monochlorobenzene
01/11/06 <1 ug/L No
Paraquat
01/11/06 <0.18 ug/L No
Parathion
01/11/06 <0.15 ug/L No
Pentachlorophenol
01/11/06 <0.11 ug/L No
Phorate
01/11/06 <0.20 ug/L No
Picloram
01/11/06 <0.04 ug/L No
Polychlorinated Biphenyls(PCB)
01/11/06 <0.23 ug/L No
Prometryne
01/11/06 <0.15 ug/L No
Simazine
2006 53 ug/L No
***THM
average
01/11/06 <0.31 ug/L No
Temephos
01/11/06 <0.12 ug/L No
Terbufos
01/11/06 <0.48 ug/L No
Tetrachloroethylene
01/11/06 <0.14 ug/L No
2,3,4,6-Tetrachlorophenol
01/11/06 <0.10 ug/L No
Triallate
01/11/06 <0.54 ug/L No
Trichloroethylene
01/11/06 <0.25 ug/L No
2,4,6-Trichlorophenol
01/11/06 <0.14 ug/L No
2,4,5-Trichlorophenoxy acetic acid (2,4,5-T)
01/11/06 <0.12 ug/L No
Trifluralin
01/11/06 <0.08 ug/L No
Vinyl Chloride
*** Annual average
List any Inorganic or Organic parameter(s) that exceeded half the standard prescribed
in Schedule 2 of Ontario Drinking Water Quality Standards.
Parameter Result Value Unit of Measure Date of Sample
Fluoride 0.8 mg/L 01/22/02
THM 53 ug/L 2006 Annual Average
(Only if DWS category is large municipal residential, small municipal residential, large municipal non residential,
small municipal non residential, large non municipal non residential)
Page 6 of 6